Manual

EcoFlow DELTA 3 Ultra Plus

Thank you for choosing EcoFlow. Sold in Malaysia at RM 10,229.

EcoFlow DELTA 3 Ultra Plus (3072Wh) Portable Power Station

Specifications

Every figure below is off EcoFlow DELTA 3 Ultra Plus's current specification sheet.

GroupSpecificationFigure
GeneralModelEF-DL-H02-3UP
GeneralDimensions613.1mm × 327.7mm × 395.0mm (79.35L)
GeneralNet weightApprox. 33.7kg
GeneralIngress protection ratingIP20
GeneralMonitoring modeLCD
GeneralFire resistanceUL94 5VA
GeneralDrop resistance≤0.2m
BatteryRated capacity3072Wh 51.2V⎓60Ah
BatteryCell chemistryLFP(LiFePO4)
BatteryBattery input port43.2V-57.6V⎓108A Max
BatteryBattery output port43.2V-57.6V⎓46A Max
BatteryProtection type• Overvoltage protection • Overload protection • Overtemperature protection • Short circuit protection • Low temperature protection • Low voltage protection • Overcurrent protection
InputAC inputCharge only & Bypass mode: • US/JP: 100-120V~15A 50/60Hz • BR\_LV: 100-127V~10A 50/60Hz • CN/UK/EU/KR/AU/CH/ZA/BR\_HV/INT: 220-240V~10A 50/60Hz
InputDC input• Solar input: 11-60V⎓18A MAX, 800W per port, total 1600W • DC input: 12V⎓8A MAX; 24V⎓8A MAX; 48V⎓16.6A MAX
OutputAC output• Discharge only: - US: 120V~60Hz 3600W total (surge 7200W), 20A (×4) Max per port, 30A(×1) Max per port - JP: 100V~60Hz 3000W total (surge 6000W), 20A (×4) Max per port, 30A(×1) Max per port - BR_LV: 127V~60Hz 3600W total (surge 7200W), 20A (×4) Max per port, - CN: 220V~50Hz 3600W total(surge 7200W ), 16A (×1) Max per port, 10A(×3) Max per port - UK: 230V~50Hz 3600W total (surge 7200W), 13A (×4) Max per port - EU: 230V~50Hz 3600W total (surge 7200W), 15.6A (×4) Max per port - KR: 220V~60Hz 3600W total (surge 7200W), 16A (×4) Max per port - BR_HV: 220V~60Hz 3600W total (surge 7200W), 16A (×4) Max per port - AU: 230V~50Hz 3600W total (surge 7200W), 15A (×4) Max per port - CH: 230V~50Hz 3600W total (surge 7200W), 10A (×2) Max per port, 15.6A (×2) Max per port - ZA: 230V~50Hz 3600W total (surge 7200W), 15.6A (×2) Max per port, 15.6A (×2) Max per port - INT: 230V~50Hz 3600W total (surge 7200W), 13A (×4) Max per port • Bypass mode: - US:100-120V~50/60Hz 3600W total , 20A (×4) Max per port, 30A (×1) Max per port - JP:100-120V~50/60Hz 3000W total, 20A (×4) Max per port, 30A (×1) Max per port - BR_LV:100-127V~50/60Hz 3600W total , 20A (×4) Max per port - CN: 220-240V~50/60Hz 3600W total, 16A (×1) Max per port, 10A (×3) Max per port - UK: 220-240V~50/60Hz 3600W total , 13A (×4) Max per port - EU: 220-240V~50/60Hz 3600W total , 15.6A (×4) Max per port - KR: 220-240V~50/60Hz 3600W total , 16A (×4) Max per port - BR_HV: 220-240V~50/60Hz 3600W total , 16A (×4) Max per port - AU: 220-240V~50/60Hz 3600W total , 15A (×4) Max per port - CH: 220-240V~50/60Hz 3600W total , 10A (×2) Max per port, 15.6A (×2) Max per port - ZA: 220-240V~50/60Hz 3600W total , 15.6A (×2) Max per port, 15.6A (×2) Max per port - INT: 220-240V~50/60Hz 3600W total , 13A (×4) Max per port Note: In bypass mode, ensure that the battery has enough power to achieve full AC output capacity. Low battery might result in limited output power.
OutputDC output• USB ouput port: - USB-A port (×1): 5V⎓3A / 9V⎓2A / 12V⎓1.5A, 18W MAX - USB-C port (×1): 5V⎓3A / 9V⎓3A / 12V⎓3A / 15V⎓3A / 20⎓5A /28V⎓5A, 140W MAX - USB-C port (×2): 5V⎓3A / 9V⎓3A / 12V⎓3A / 15V⎓3A / 20V⎓2.25A, 45W MAX per port, total 45W • Anderson output port: 12.6V⎓30A, 378W MAX • Cigarette lighter output port: 12.6V⎓10A, 126W MAX
OutputCommunicationWi-Fi / Bluetooth

Error Icons And Warnings

What the screen is telling you, and what to do about it here.

IndicatorWhat It Means
1High temperature
2Battery error
3System error code
4Low temperature
5Overload

Warranty In Malaysia

24 months on the unit and 60 months on the battery, honoured here, by us. Register the serial number once and the cover is on record before you ever need it.

Service And Support

Faults are handled in Malaysia — you send it to us, not overseas. Open a case and you get a case number, an assessment target and somewhere to track it.

For anything urgent, message the technical line on technical.

Common Questions

What warranty does the DELTA 3 Ultra Plus carry in Malaysia?

24 months on the unit and 60 months on the battery, honoured in Malaysia by the authorised distributor. Register the serial number once and the cover is on record before you need it.

What is the DELTA 3 Ultra Plus's battery capacity?

3072Wh 51.2V⎓60Ah. Capacity is the figure that decides how long it runs a given load, so it is the first number to check against what you intend to power.

What can the DELTA 3 Ultra Plus run?

Its AC output is rated • Discharge only: - US: 120V~60Hz 3600W total (surge 7200W), 20A (×4) Max per port, 30A(×1) Max per port - JP: 100V~60Hz 3000W total (surge 6000W), 20A (×4) Max per port, 30A(×1) Max per port - BR_LV: 127V~60Hz 3600W total (surge 7200W), 20A (×4) Max per port, - CN: 220V~50Hz 3600W total(surge 7200W ), 16A (×1) Max per port, 10A(×3) Max per port - UK: 230V~50Hz 3600W total (surge 7200W), 13A (×4) Max per port - EU: 230V~50Hz 3600W total (surge 7200W), 15.6A (×4) Max per port - KR: 220V~60Hz 3600W total (surge 7200W), 16A (×4) Max per port - BR_HV: 220V~60Hz 3600W total (surge 7200W), 16A (×4) Max per port - AU: 230V~50Hz 3600W total (surge 7200W), 15A (×4) Max per port - CH: 230V~50Hz 3600W total (surge 7200W), 10A (×2) Max per port, 15.6A (×2) Max per port - ZA: 230V~50Hz 3600W total (surge 7200W), 15.6A (×2) Max per port, 15.6A (×2) Max per port - INT: 230V~50Hz 3600W total (surge 7200W), 13A (×4) Max per port • Bypass mode: - US:100-120V~50/60Hz 3600W total , 20A (×4) Max per port, 30A (×1) Max per port - JP:100-120V~50/60Hz 3000W total, 20A (×4) Max per port, 30A (×1) Max per port - BR_LV:100-127V~50/60Hz 3600W total , 20A (×4) Max per port - CN: 220-240V~50/60Hz 3600W total, 16A (×1) Max per port, 10A (×3) Max per port - UK: 220-240V~50/60Hz 3600W total , 13A (×4) Max per port - EU: 220-240V~50/60Hz 3600W total , 15.6A (×4) Max per port - KR: 220-240V~50/60Hz 3600W total , 16A (×4) Max per port - BR_HV: 220-240V~50/60Hz 3600W total , 16A (×4) Max per port - AU: 220-240V~50/60Hz 3600W total , 15A (×4) Max per port - CH: 220-240V~50/60Hz 3600W total , 10A (×2) Max per port, 15.6A (×2) Max per port - ZA: 220-240V~50/60Hz 3600W total , 15.6A (×2) Max per port, 15.6A (×2) Max per port - INT: 220-240V~50/60Hz 3600W total , 13A (×4) Max per port Note: In bypass mode, ensure that the battery has enough power to achieve full AC output capacity. Low battery might result in limited output power. That rating, not the capacity, is what decides whether an appliance will start at all.

How heavy is the DELTA 3 Ultra Plus?

Approx. 33.7kg. Worth knowing before you plan to carry it — weight is the specification most often discovered after delivery.

Where do I get the DELTA 3 Ultra Plus serviced in Malaysia?

Through us. Faults are assessed here rather than shipped overseas — open a case and you get a case number, an assessment target and somewhere to track it.

The Manufacturer's Manual

EcoFlow publishes this manual as a web page rather than a PDF. It is the authoritative document for operation and safety; this page states the figures and what they mean for an owner in Malaysia.